ECOCAT

T 4.16 DV pressure vacuum pumps

The robust rotary vane pump T 4.16 DV is suitable for higher pressure differences in vacuum and/or pressure applications. An eccentrically mounted rotor with slits in which precisely fitting slides move and separate the individual working chambers rotates in a cylindrical housing.
Nhà sản xuất: Becker
Liên hệ
air volumerelative pressure/vacuumemission sound pressure levelweight with engine
m³/hbardB(A)kg
50Hz60Hz50Hz60Hz50Hz60Hz
1620±0.5±0.56163about 24

T 4.16 DV pressure-vacuum pumps 3∼ motors Technical data

50Hz60Hzexecution
kWVat least-1AkwVat least-1A
0,55Δ230/Y400 (IE2)14453,10 – 1,790,7Δ265/Y460 (IE2)
Δ230/Y400 (IE2)
Δ208/Y360 (IE2)
1740
1715
1690
3,05 – 1,76
3,03 – 1,75
3,14 – 1,81
IP55 • ISO F
PTO bimetallic 150°C

 

T 4.16 DV Pressure-Vacuum Pumps 1∼ Engine Technical Data

50Hz60Hzexecution
kWVat least-1AkwVat least-1A
0,55230±10%13604,60,66230±10%16005,2IP54 • ISO F
20uF (450V)
    0,66115±6%16309,5UL(E123782)
IP54 • ISO F
80uF (240V)

 

Air volumes - power consumption - temperatures

  relative pressure(bar)50 Hz - relative vacuum (bar)
60 Hz - relative vacuum (bar)
  0-0,25-0,50-0,25-0,5
amount of suction airm³/h0.25 bars15,511,16,518,113,38,0
blown air volumem³/h15,511,16,518,113,38,0
power consumptionkW0,420,430,430,520,560,54
blast air temperature°C606674687381
amount of suction airm³/h0.5 bars1510,1617,912,37,3
blown air volumem³/h1510,1617,912,37,3
power consumptionkW0,480,480,530,580,590,62
blast air temperature°C697783768391